HKZS-100D Single syringe with drug library

HKZS-100D Single syringe with drug library
Product Detailed
HKZS-100D Single syringe with drug library 1.With maximum 8 channels 2.Unique Voice Alarm system 3.Large LCD screen

HKZS-100D   Single syringe with drug library

Features & Functions:

1. Freely Stackable: Users can freely stack one syringe pump onto another to provide multiple Solutions, which have a wide range of clinical applications.

2. Stackable to be the maximum 8 channels.

3. Transfer the message between the Nurse-call System and the pumps.

4. Three working modes: rate mode, time-volume mode, dosage-weight mode.

5. Unique Voice Alarm system and accurate injection rate make the injection process safer and more reliable.

6. Have store many brands syringes, automatically calibration and compatible with any brand syringes.

7. Large LCD screen displays working status.

8. KVO and Bolus functions.

9. Has drug library with more than 500 drugs.

10. Has 2000 records.

Technical parameters:

Product name

Stackable syringe pump with drug library HKZS-100D

Unique Voice 

Alarm system

The device triggered the voice prompt and stop injection 

automatically when there is any malfunction, making the 

infusion process safer and more reliable.

Flow rate

50ml syringe:0.1~1500ml/h;

30ml syringe:0.1~900.0ml/h;

20ml syringe:0.1~600.0ml/h;

10ml syringe:0.1~300.0ml/h

The range of 

limiting volume

0~999.9ml

The range of 

injected volume

0~9999.9ml

Accuracy of 

flow rate

Within ±3%(Choose the syringe of specified manufacturer 

correctly. This accuracy of flow rate is not including the 

errors of syringe itself.)

Purge rate

Purge rate of 50ml syringe:1500ml/h;

Purge rate of 30ml syringe:900.0ml/h;

Purge rate of 20ml syringe:600.0ml/h;

Purge rate of 10ml syringe:300.0ml/h

Alarm and 

warms

The pump can give out alarming when injection soon finish, 

injection finishing, injection of limited amount finished, 

injection is blocked, syringe falls off, syringe is improperly 

installed, setting error, AC power has been pulled out, low 

battery and so on.  

Injection blocked

Choose in the three kinds of occlusion alarm pressure 

according to the clinical requirements(High, Medium, Low)

KVO rate

1ml/h

Fuse specification

F1AL/250V ,two fuses(installed inside pump)

Operating power

AC100~240.0V, 50/60Hz,  Power:≤30VA

Internal rechargeable battery: DC 11.1V,

capacity≥1600mAh. The device could work constantly 

more than 4 hour at medium speed running mode, 

after the battery charged for 10 hours.

Operating 

environment

temperature:+5~+40°C,  relative humidity:20~90%

Storing environment

temperature:-30°C~+55, relative humidity:≤95%, 

( No condensation state )

Atmospheric 

pressure

860hPa~1060hPa

Safety level

Class II with insulated enclosure, internal 

power supply, BF-type continuous normal 

running equipment.

IP grade

IPX1

Dimensions

280(L)×210(W)×130(H)(mm)

Weight

2.2kg

Accessories

Power line, operating manual, warranty card, 

product certification.

HKZS-100D Single syringe with drug library